TERMICOL HEAT EXCHANGER: THX5, THX10

Description

  • Heat pump for the production of DHW for use in existing tanks
  • The system allows the user to benefit from the economic savings of heat pump technology by taking advantage of any tank installed
garantia-2-in-95

Features

  • Energy savings: up to 75% compared to conventional systems for DHW production
  • DHW up to 55ºC only with heat pump
  • Allows dehumidifying and cooling spaces
  • Indoor / outdoor connection
  • Connection with photovoltaic installations
  • Efficient fan with low acoustic impact
  • Automatic anti-legionella disinfection
  • Intelligent controller with 3 modes of operation
  • Possibility of floor or wall installation
  • The outlet air stream can be used to cool spaces
 

 

 

Technical dataUnitsTHX5THX10
Nominal capacityL100 – 280280 – 500
SCOP at 7ºC *2,542,87
SCOP at 14ºC **2,913,01
Thermal power range (7ºC – 14ºC)W1464 – 18203122 – 3907
Consumed power range (7ºC – 14ºC)W464 – 4931082 – 1145
Maximum consumptionW6351200
Max temp. outlet waterºC5555
Electrical power supplyV / ph / Hz220 – 240 / 1 / 50220 – 240 / 1 / 50
Loadg9501285
Airflowm3/h350 – 450700
Temperature min. of airºC-5-5
Pressure available at the fanPa7070
Exchanger pressure dropkPa22
Min. Water flowL /h250483

 

 

ModelReferenceInstalationEnergy classSound pressure (dB) *
THX5651HP05Floor / MuralA41
THX10651HP10Floor / MuralA41

* Sound pressure measured according to EN12102 and EN9614 at 5m distance and directivity

EQUIPMENT SCHEME

 

ReferenceDescription
AElectric connection
BCondensate outlet
WAir intake
DAir blasting
EHot water outlet
fCold water inlet
GTemperature probe / pump connection

THX5 MEASURES

MEASURES THX10

Refrigerating circuitDescription
CompressorRotative
RefrigerantR134a
EvaporatorCopper tube and aluminum fins
Plate heat exchangerStainless steel
ConnectionsTHX5THX10
Hot water outlet (inch)3/41
Cold water inlet (inch)3/41
Air connection diameter (mm)160160

ADVANCED CONTROLLER

    • Touch screen controller
    • Possibility of adaptation with photovoltaic installations
    • Automatic anti-legionella disinfection
    • Automatic defrost when the evaporator is frozen
    • Alarms:
      • Low pressure, high pressure
      • High operating temperature
      • Temperature probe
      • Battery fault
    • It incorporates 3 operating modes:
        • Eco: heat pump only operating mode
        • Auto: combination of electric resistance heat pump for faster heating
        • Boost: heat pump and electric resistance for faster heating