TERMICOL HEAT PUMP: 200, 260L

  • Maximum energy efficiency.
  • Guarantees minimal heat losses thanks to its insulation
  • Easy installation and access: very similar to thermoelectric.
  • Up to 65ºC maximum temperature only with heat pump.
  • Anti-legionella disinfection.
  • Efficient fan with low acoustic impact.
  • Automatic anti-legionella disinfection
  • Connection and integration with other renewable energy sources such as photovoltaic or solar thermal systems.
  • Self-diagnosis system.
  • 5-year guarantee for the tank and 2 years for the rest of the components.
Technical dataUnitsTHPT200*THP200THP260*THP200
Nominal capacityL194220280 – 500280 – 500
Maximun working pressurebar882,872,87
SCOP at 7ºC2,82,83,013,01
SCOP at 14ºC3,13,13122 – 39073122 – 3907
Potencia nominal at 7ºCW1.1001.1001082 – 11451082 – 1145
Heat pump consumptionW43043012001200
Max. heat pump currentA9.69.65555
Maximum consumption with standW2.1632.163220 – 240 / 1 / 50220 – 240 / 1 / 50
Maximum water temperature with BCºC656512851285
Maximum water temperature with resistanceºC7575700700
Power supply (frequency)V (Hz)1/N/230 (50)1/N/230 (50)1/N/230 (50)1/N/230 (50)
Electric resistance powerW1.5001.5001.5001.500
Insulation typePUPUPUPU
Average insulation thickness cm483483483483
Maximun working pressurebar5555
Equipment airflow rangem3/h314314314314

 

 

ModelReferenceInstalationEnergy classSound pressure (dB) *
THPT200650HPT200FloorA+31
THPT260650HPT260FloorA+31
THPT200S*650HPT200SFloorA+31
THPT260S*650HPT200SFloorA+31

* Sound pressure measured according to EN12102 and EN9614 at 5m distance and directivity

EQUIPMENT SCHEME

Refrigerating circuitDescription
CompressorRotative
RefrigerantR134a
EvaporatorCentrifugal
CondenserAluminum
ReferenceDescriptionConnections
CWCold water inlet1″
HWHot water outlet1″
ISEntrada serpentín*1″
OSSerpentine output *1″
RRecirculation3/4″
TSThermostat connection1/2″
EEOpening for electrical resistance1/2″
CDCondensate drainage3/4″

 

Measurement

ADVANCED CONTROLLER

    • Intuitive, programmable controller with LCD display
    • Prepared for connection with solar thermal and photovoltaic installations.
    • Automatic anti-legionella disinfection
    • Automatic defrost when the evaporator is frozen
    • When an error occurs or the protection mode is activated automatically,
      the error number will be indicated on the control panel display and a symbol will flash
      on the controller board.
    • Operating modes:
        • Normal mode: the system logic will constantly calculate the maximum value of
          the compressor operation whenever the ambient temperature exceeds 25ºC,
          only activating the electrical resistance until reaching
          the temperature set by the user when the compressor reaches the max.
          Temperature. calculated to avoid its malfunction.
        • Fast heating mode: the electric resistance will start working at the same time as
          the compressor, until it reaches the temperature set by the
          user.
        • Electric resistance mode: only the electric resistance will act.