TERMICOL HEAT EXCHANGER: THX5, THX10
Description
- Heat pump for the production of DHW for use in existing tanks
- The system allows the user to benefit from the economic savings of heat pump technology by taking advantage of any tank installed

Features
- Energy savings: up to 75% compared to conventional systems for DHW production
- DHW up to 55ºC only with heat pump
- Allows dehumidifying and cooling spaces
- Indoor / outdoor connection
- Connection with photovoltaic installations
- Efficient fan with low acoustic impact
- Automatic anti-legionella disinfection
- Intelligent controller with 3 modes of operation
- Possibility of floor or wall installation
- The outlet air stream can be used to cool spaces

Technical data | Units | THX5 | THX10 |
---|---|---|---|
Nominal capacity | L | 100 – 280 | 280 – 500 |
SCOP at 7ºC * | – | 2,54 | 2,87 |
SCOP at 14ºC ** | – | 2,91 | 3,01 |
Thermal power range (7ºC – 14ºC) | W | 1464 – 1820 | 3122 – 3907 |
Consumed power range (7ºC – 14ºC) | W | 464 – 493 | 1082 – 1145 |
Maximum consumption | W | 635 | 1200 |
Max temp. outlet water | ºC | 55 | 55 |
Electrical power supply | V / ph / Hz | 220 – 240 / 1 / 50 | 220 – 240 / 1 / 50 |
Load | g | 950 | 1285 |
Airflow | m3/h | 350 – 450 | 700 |
Temperature min. of air | ºC | -5 | -5 |
Pressure available at the fan | Pa | 70 | 70 |
Exchanger pressure drop | kPa | 2 | 2 |
Min. Water flow | L /h | 250 | 483 |
Model | Reference | Instalation | Energy class | Sound pressure (dB) * |
---|---|---|---|---|
THX5 | 651HP05 | Floor / Mural | A | 41 |
THX10 | 651HP10 | Floor / Mural | A | 41 |
* Sound pressure measured according to EN12102 and EN9614 at 5m distance and directivity
EQUIPMENT SCHEME
Reference | Description |
---|---|
A | Electric connection |
B | Condensate outlet |
W | Air intake |
D | Air blasting |
E | Hot water outlet |
f | Cold water inlet |
G | Temperature probe / pump connection |

THX5 MEASURES

MEASURES THX10

Refrigerating circuit | Description |
---|---|
Compressor | Rotative |
Refrigerant | R134a |
Evaporator | Copper tube and aluminum fins |
Plate heat exchanger | Stainless steel |
Connections | THX5 | THX10 |
---|---|---|
Hot water outlet (inch) | 3/4 | 1 |
Cold water inlet (inch) | 3/4 | 1 |
Air connection diameter (mm) | 160 | 160 |
ADVANCED CONTROLLER
-
- Touch screen controller
- Possibility of adaptation with photovoltaic installations
- Automatic anti-legionella disinfection
- Automatic defrost when the evaporator is frozen
- Alarms:
- Low pressure, high pressure
- High operating temperature
- Temperature probe
- Battery fault
- It incorporates 3 operating modes:
-
- Eco: heat pump only operating mode
-
- Auto: combination of electric resistance heat pump for faster heating