TERMICOL HEAT PUMP: 200, 260L

  • Maximum energy efficiency.
  • Guarantees minimal heat losses thanks to its insulation
  • Easy installation and access: very similar to thermoelectric.
  • Up to 65ºC maximum temperature only with heat pump.
  • Anti-legionella disinfection.
  • Efficient fan with low acoustic impact.
  • Automatic anti-legionella disinfection
  • Connection and integration with other renewable energy sources such as photovoltaic or solar thermal systems.
  • Self-diagnosis system.
  • 5-year guarantee for the tank and 2 years for the rest of the components.
Technical data Units THPT200* THP200 THP260* THP200
Nominal capacity L 194 220 280 – 500 280 – 500
Maximun working pressure bar 8 8 2,87 2,87
SCOP at 7ºC 2,8 2,8 3,01 3,01
SCOP at 14ºC 3,1 3,1 3122 – 3907 3122 – 3907
Potencia nominal at 7ºC W 1.100 1.100 1082 – 1145 1082 – 1145
Heat pump consumption W 430 430 1200 1200
Max. heat pump current A 9.6 9.6 55 55
Maximum consumption with stand W 2.163 2.163 220 – 240 / 1 / 50 220 – 240 / 1 / 50
Maximum water temperature with BC ºC 65 65 1285 1285
Maximum water temperature with resistance ºC 75 75 700 700
Power supply (frequency) V (Hz) 1/N/230 (50) 1/N/230 (50) 1/N/230 (50) 1/N/230 (50)
Electric resistance power W 1.500 1.500 1.500 1.500
Insulation type PU PU PU PU
Average insulation thickness cm 483 483 483 483
Maximun working pressure bar 5 5 5 5
Equipment airflow range m3/h 314 314 314 314

 

 

Model Reference Instalation Energy class Sound pressure (dB) *
THPT200 650HPT200 Floor A+ 31
THPT260 650HPT260 Floor A+ 31
THPT200S* 650HPT200S Floor A+ 31
THPT260S* 650HPT200S Floor A+ 31

* Sound pressure measured according to EN12102 and EN9614 at 5m distance and directivity

EQUIPMENT SCHEME

Refrigerating circuit Description
Compressor Rotative
Refrigerant R134a
Evaporator Centrifugal
Condenser Aluminum
Reference Description Connections
CW Cold water inlet 1″
HW Hot water outlet 1″
IS Entrada serpentín* 1″
OS Serpentine output * 1″
R Recirculation 3/4″
TS Thermostat connection 1/2″
EE Opening for electrical resistance 1/2″
CD Condensate drainage 3/4″

 

Measurement

ADVANCED CONTROLLER

    • Intuitive, programmable controller with LCD display
    • Prepared for connection with solar thermal and photovoltaic installations.
    • Automatic anti-legionella disinfection
    • Automatic defrost when the evaporator is frozen
    • When an error occurs or the protection mode is activated automatically,
      the error number will be indicated on the control panel display and a symbol will flash
      on the controller board.
    • Operating modes:
        • Normal mode: the system logic will constantly calculate the maximum value of
          the compressor operation whenever the ambient temperature exceeds 25ºC,
          only activating the electrical resistance until reaching
          the temperature set by the user when the compressor reaches the max.
          Temperature. calculated to avoid its malfunction.
        • Fast heating mode: the electric resistance will start working at the same time as
          the compressor, until it reaches the temperature set by the
          user.
        • Electric resistance mode: only the electric resistance will act.